The LROFC1104 is a LG column refrigerator (11.4 cu ft). Sold since 2026.
Status
Currently Sold
Years Sold
2026 – Present
Capacity
11.4 cu ft
Width
23.5 in
Height
73.25 in
Wi-Fi
No
Parts & Labor
1 year parts and labor
1 year internal/functional parts and labor
Smart Diagnosis™
Smart Inverter Compressor
Multi-Air Flow
No Frost Cooling System
Zero Clearance
ENERGY STAR® Certified
ENERGY STAR®
Multi Air Flow Cooling
Smart Inverter
Multi-Air Flow System
Recalls
None on file
verified Sep 2026
Written from the record's fields, not from reviews. Covers the LROFC1104 generation (LROFC1104V) only. Years sold from the manual date. Sources: LG warranty
Expected lifespan is ApplianceEdge's estimate, formed from category lifetime data, service records and warranty terms. It is not a prediction for your unit and not a manufacturer figure — with proper care and maintenance, many appliances last well beyond this range. Everything else on this tab is written from the record's fields. Sources: LG warranty
What to Expect
LG runs its own factory service in most major metros, with authorized local servicers everywhere else. Genuine parts go through Encompass Parts Distribution and LG's own store, so independents can get them. Before paying for a compressor repair, check the 10-year compressor term — it's parts only, but it's real. Full warranty terms are in Owning It.
Communication error between the main control board and the display PCB (unstable power, wire disconnection or component failure).
What to do
Unplug the power cord (or trip the breaker), wait about 5 minutes, restore power.
CO
Communication error between the main control board and the display PCB (unstable power, wire disconnection or component failure).
Unplug the power cord (or trip the breaker), wait about 5 minutes, restore power.
Meaning
Defrost failure — the defrost cycle did not raise temperature sufficiently (LG: > 1 hour / 80 minutes). Causes named by LG: ice accumulation, blocked drain, thermal fuse, heater disconnection, main PCB.
What to do
Unplug for ~2 minutes to reset (code list). If ice is present: Unplug the unit, open the doors fully and let ice melt (LG: 8+ hours on the code list; 1 day in summer / 3 days in winter on the FF/dH articles); let water drain to the drain tray. Move food if spoilage is a concern.
dH
Defrost failure — the defrost cycle did not raise temperature sufficiently (LG: > 1 hour / 80 minutes). Causes named by LG: ice accumulation, blocked drain, thermal fuse, heater disconnection, main PCB.
Unplug for ~2 minutes to reset (code list). If ice is present: Unplug the unit, open the doors fully and let ice melt (LG: 8+ hours on the code list; 1 day in summer / 3 days in winter on the FF/dH articles); let water drain to the drain tray. Move food if spoilage is a concern.
Meaning
Door motor does not reach the maximum/home position within 5 seconds.
dr
Door motor does not reach the maximum/home position within 5 seconds.
Meaning
Defrost sensor short or disconnection; evaporator ice blockage risk.
dS
Defrost sensor short or disconnection; evaporator ice blockage risk.
Meaning
Freezer-compartment ice maker sensor failure.
EID
Freezer-compartment ice maker sensor failure.
Meaning
Freezer-compartment ice maker assembly failure.
EIU
Freezer-compartment ice maker assembly failure.
Meaning
Freezer fan motor error — no signal from the freezer fan motor; frost/ice buildup can lock the fan.
What to do
Unplug the power cord (or trip the breaker), wait about 5 minutes, restore power. If frost is suspected: Unplug the unit, open the doors fully and let ice melt (LG: 8+ hours on the code list; 1 day in summer / 3 days in winter on the FF/dH articles); let water drain to the drain tray. Move food if spoilage is a concern.
FF
Freezer fan motor error — no signal from the freezer fan motor; frost/ice buildup can lock the fan.
Unplug the power cord (or trip the breaker), wait about 5 minutes, restore power. If frost is suspected: Unplug the unit, open the doors fully and let ice melt (LG: 8+ hours on the code list; 1 day in summer / 3 days in winter on the FF/dH articles); let water drain to the drain tray. Move food if spoilage is a concern.
Meaning
Freezer temperature sensor short or disconnection.
FS
Freezer temperature sensor short or disconnection.
Meaning
Cycle error — freezer temperature does not fall below 3.5°C within 10 minutes.
What to do
Unplug the power cord (or trip the breaker), wait about 5 minutes, restore power. Check temperature settings and door seals.
FU
Cycle error — freezer temperature does not fall below 3.5°C within 10 minutes.
Unplug the power cord (or trip the breaker), wait about 5 minutes, restore power. Check temperature settings and door seals.
Meaning
Water flow sensor error or low water pressure (closed tap, kinked hose, pressure).
What to do
Check the water tap is open, the hose is not kinked, and increase water pressure.
gF
Water flow sensor error or low water pressure (closed tap, kinked hose, pressure).
Check the water tap is open, the hose is not kinked, and increase water pressure.
Meaning
High ambient temperature warning (above +50°C); performance may be affected.
What to do
Not a fault; performance warning.
HI
High ambient temperature warning (above +50°C); performance may be affected.
Not a fault; performance warning.
Meaning
Humidity sensor short or disconnection.
HS
Humidity sensor short or disconnection.
Meaning
Ice maker fan error — blockage or fan fault; frost buildup possible.
What to do
Unplug the unit, open the doors fully and let ice melt (LG: 8+ hours on the code list; 1 day in summer / 3 days in winter on the FF/dH articles); let water drain to the drain tray. Move food if spoilage is a concern.
IF
Ice maker fan error — blockage or fan fault; frost buildup possible.
Unplug the unit, open the doors fully and let ice melt (LG: 8+ hours on the code list; 1 day in summer / 3 days in winter on the FF/dH articles); let water drain to the drain tray. Move food if spoilage is a concern.
Meaning
Ice maker sensor error / ice maker fan motor or sensor disconnection; ice is no longer dispensed.
IS
Ice maker sensor error / ice maker fan motor or sensor disconnection; ice is no longer dispensed.
Meaning
Ice maker motor error / defect in the ice maker.
It
Ice maker motor error / defect in the ice maker.
Meaning
Low ambient temperature warning (below −10°C); performance may be affected.
What to do
Not a fault; performance warning.
L0
Low ambient temperature warning (below −10°C); performance may be affected.
Not a fault; performance warning.
Meaning
Wi-Fi modem or communication error.
Od
Wi-Fi modem or communication error.
Meaning
Display off / demo (showroom) mode — cooling is disabled.
What to do
Press and hold REFRIGERATOR and ICE PLUS for 5 seconds (button pair varies by model).
OF F
Display off / demo (showroom) mode — cooling is disabled.
Press and hold REFRIGERATOR and ICE PLUS for 5 seconds (button pair varies by model).
Meaning
Refrigerator temperature sensor (R2, lower) fault.
r2
Refrigerator temperature sensor (R2, lower) fault.
Meaning
Refrigerator compartment fan motor error — fan motor not operating normally; frost buildup possible.
What to do
Unplug the power cord (or trip the breaker), wait about 5 minutes, restore power. If frost is suspected: Unplug the unit, open the doors fully and let ice melt (LG: 8+ hours on the code list; 1 day in summer / 3 days in winter on the FF/dH articles); let water drain to the drain tray. Move food if spoilage is a concern.
rF
Refrigerator compartment fan motor error — fan motor not operating normally; frost buildup possible.
Unplug the power cord (or trip the breaker), wait about 5 minutes, restore power. If frost is suspected: Unplug the unit, open the doors fully and let ice melt (LG: 8+ hours on the code list; 1 day in summer / 3 days in winter on the FF/dH articles); let water drain to the drain tray. Move food if spoilage is a concern.
Meaning
Refrigerator temperature sensor (R1, upper) short or disconnection.
rS
Refrigerator temperature sensor (R1, upper) short or disconnection.
Meaning
Ambient (room) temperature sensor short or open.
rT
Ambient (room) temperature sensor short or open.
Meaning
Sabbath mode is active (lights, alarms and dispenser disabled; auto-off after 96 hours).
What to do
Press and hold Freezer and Wi-Fi for 3 seconds (varies by model).
Sb
Sabbath mode is active (lights, alarms and dispenser disabled; auto-off after 96 hours).
Press and hold Freezer and Wi-Fi for 3 seconds (varies by model).
Meaning
Pantry / water tank sensor short or open.
SS
Pantry / water tank sensor short or open.
Meaning
Water tank error — tank missing, misaligned, or sensor malfunction.
tt
Water tank error — tank missing, misaligned, or sensor malfunction.
Cooling
Cooling repairs are sealed-system work — check the compressor coverage before paying.
Repair
What’s involved
DIY
Parts
Labor
DIY
Advanced DIY
What’s involved
The technician accesses the concealed evaporator section, checks fan voltage and ice obstruction, and replaces the failed fan motor or assembly.
Parts
Evaporator Fan Motor
$80–$90
Air Damper
$105–$120
Labor
$250–$425
evaporator fan motor
The technician accesses the concealed evaporator section, checks fan voltage and ice obstruction, and replaces the failed fan motor or assembly.
Advanced DIY
Evaporator Fan Motor
$80–$90
Air Damper
$105–$120
$250–$425
DIY
Advanced DIY
What’s involved
The evaporator is manually cleared and the failed heater, sensor, thermostat, wiring, or control output is identified and replaced.
Parts
Defrost thermostat / evaporator defrost sensor
$25–$70
Defrost heater
$40–$110
Electronic / adaptive defrost control board
$150–$300
Labor
$125–$425
defrost system failure — heater, sensor, thermostat, or control output
The evaporator is manually cleared and the failed heater, sensor, thermostat, wiring, or control output is identified and replaced.
Advanced DIY
Defrost thermostat / evaporator defrost sensor
$25–$70
Defrost heater
$40–$110
Electronic / adaptive defrost control board
$150–$300
$125–$425
DIY
Advanced DIY
What’s involved
Water pressure, fill-valve operation, freezer temperature, and harvest are tested before replacing the failed ice maker or inlet valve.
Parts
Ice Maker Assembly
$200–$210
Water Inlet Valve
$85–$90
Labor
$150–$425
ice maker assembly or water inlet valve
Water pressure, fill-valve operation, freezer temperature, and harvest are tested before replacing the failed ice maker or inlet valve.
Advanced DIY
Ice Maker Assembly
$200–$210
Water Inlet Valve
$85–$90
$150–$425
DIY
Advanced DIY
What’s involved
Power, sensors, fans, valves, and compressor commands are verified before the failed board is replaced and programmed where required.
Parts
Main Control Board
$215–$230
Labor
$250–$425
main electronic control board or user-interface board
Power, sensors, fans, valves, and compressor commands are verified before the failed board is replaced and programmed where required.
Advanced DIY
Main Control Board
$215–$230
$250–$425
DIY
Advanced DIY
What’s involved
The heavy door and cabinetry clearances are aligned and the worn gasket, hinge, closer, or mounting hardware is replaced.
Parts
Door Gasket
$115–$185
Labor
$125–$250
door gasket, hinge, closer, or alignment hardware
The heavy door and cabinetry clearances are aligned and the worn gasket, hinge, closer, or mounting hardware is replaced.
Advanced DIY
Door Gasket
$115–$185
$125–$250
DIY
Advanced DIY
What’s involved
The drain path and pressurized water lines are isolated, then thawed, cleared, repaired, or replaced with cabinet access restored afterward.
Parts
Drain tube / P-trap
$40–$45
Water tubing
$25–$65
Labor
$250–$425
blocked defrost drain, drain-pan heater, or leaking water tubing
The drain path and pressurized water lines are isolated, then thawed, cleared, repaired, or replaced with cabinet access restored afterward.
Advanced DIY
Drain tube / P-trap
$40–$45
Water tubing
$25–$65
$250–$425
DIY
Advanced DIY
What’s involved
Actual temperatures and sensor resistance are compared and the failed sensor, damper, or harness is replaced.
Parts
Thermistor / temperature sensor
$25–$75
Air damper / diffuser control
$50–$200
Main electronic control board
$150–$300
Labor
$125–$325
thermistor, air damper, or zone-control sensor
Actual temperatures and sensor resistance are compared and the failed sensor, damper, or harness is replaced.
Advanced DIY
Thermistor / temperature sensor
$25–$75
Air damper / diffuser control
$50–$200
Main electronic control board
$150–$300
$125–$325
DIY
Advanced DIY
What’s involved
The concealed condenser area is cleaned, airflow and voltage are checked, and the failed fan motor or blade is replaced.
Parts
Condenser Fan Motor
$75–$105
Labor
$250–$425
condenser fan motor
The concealed condenser area is cleaned, airflow and voltage are checked, and the failed fan motor or blade is replaced.
Advanced DIY
Condenser Fan Motor
$75–$105
$250–$425
DIY
Technician job
What’s involved
A factory-authorized or EPA-certified technician pressure-tests the affected refrigeration circuit and repairs the leak or replaces the compressor, filter-drier, and related sealed-system components.
Parts
Compressor
$850–$1,000
Evaporator assembly / refrigerant leak
$625–$1,050
Labor
$500–$850
compressor or sealed-system leak/restriction
A factory-authorized or EPA-certified technician pressure-tests the affected refrigeration circuit and repairs the leak or replaces the compressor, filter-drier, and related sealed-system components.
Technician job
Compressor
$850–$1,000
Evaporator assembly / refrigerant leak
$625–$1,050
$500–$850
DIY
Easy DIY
What’s involved
The condenser and grille are professionally cleaned and required cabinet ventilation and fan airflow are restored.
Parts
$0–$30
Labor
$145–$145
dirty or obstructed condenser / ventilation problem
The condenser and grille are professionally cleaned and required cabinet ventilation and fan airflow are restored.
Easy DIY
$0–$30
$145–$145
Easy DIY: basic tools, under an hour. Moderate: some disassembly. Advanced: experience with the machine's internals. Technician: sealed-system, electrical or tub-split work.
Parts prices don’t move much across the country; labor does. If a technician supplies the part, expect 40–50% on top of the part price.
Error codes and known issues come from manufacturer documents and public records, not from reviews. Sources: LG product page · LG warranty
This page draws on the ApplianceEdge Registry — 2,600 appliance families connected to more than 9,400 verified models, independently researched. We don’t know everything about this family yet, and we won’t pretend to: finish records and filter and accessory cross-references for this platform are still being verified. We only publish what we can stand behind, and the gaps close as the Registry grows.
ApplianceEdge assessments — lifespans, repair values, and reliability notes — are our editorial opinions, built from documented third-party sources: owner reports, industry pricing data, manufacturer literature, and official records. They describe patterns across a product family, not any individual machine; your experience may differ. Recall information links directly to official CPSC notices. We accept no payment from manufacturers, and no brand influences what we publish.
See what LG has on sale today
Current LG promotions, plus offers from similar brands.
ApplianceEdge is not currently compensated for referrals made through links on this site. Links to products, retailers, and service providers are provided for convenience only. Our recommendations are based on ownership experience, reliability considerations, serviceability, and household fit—not compensation. No manufacturer or retailer pays for placement or favorable coverage.